EXPANSION VESSELS

HOW IT WORKS

Expansion Vessels

The expansion vessels compensate the variations in pressure due to the expansion or reduction of the volume of water, resulting from changes in temperature.
The Officine Varisco vessels are pressurised without a diaphragm and they satisfy the safety requirements of large-sized plants, such as hospitals, sport centres, airports and power station.
They are also used in plants where the temperature or the characteristics of fluids are incompatible with the rubber membranes of the vessels with a diaphragm.
The OFFICINE VARISCO expansion vessels are CE approved, according to the 97/23/CE (PED) Directive.

CLOSED WITHOUT DIAPHRAM

The expansion vessels are composed by a carbon steel pressure vessel built and tested in accordance with the Directive 2014/68/EU of the European Parliament.

PRESURRIZED BY AIR

During the phase of installation, the expansion vessels are pressurized by an air compressor or by air compressed with a major pressure of the hydrostatic pressure where the expansion vessel is installed.

CONSTANT PRESSURE, VARIABLE LEVEL

The working pressure is kept constant with the expulsion of the air in excess during the phases of water expansion (water heating) and/or the potential release of a new compressed air during the phase of downturn (water cooling).

CHECK OF PUTTING INTO SERVICE AND FOLLOWING CHECKS

The expansion vessels of a cylinder are provided with all the accessories according to the current rules to guarantee its automatic and safe function and they have been certified by Ministerial Decree on the regulation providing norms to put into service and using pressure equipment and the assemblies. The checks are carried out in the factory therefore every cylinder can be exempt by the putting into service test.

Expansions Vessels
Expansion Vessels

1 – Command probe for water release

2 – Safety probe for setting minimum level

3 – Pressure gauge with three way faucet

4 – Pressure switch for air expulsion

5 – Expansion vessel

6 – Data plate

7 – Switchboard

8 – Safety relief valve

9 – Stop probe for water releasing

10 – Solenoid valve for air expulsion

11 – Pressure switch to set the air release

12 – Level indicator

13 – Shut-off valve for Air Vent

14 – Solenoid valve for air expulsion

15 – Non-return valve

16 – Air compressor

17 – Retention valves and shut-off valves

18 – Solenoid valve for air release

19 – Pressure regulator with filter and pressure gauge

Targhetta Officine Varisco

CERTIFICATION CE N.2014/68/UE – The heat exchangers are designed, built and tested according to European directive 2014/68/UE on pressure appliances (PED).

RATING PLATE – Each heat exchanger is fitted with a “number plate” showing the specifications.
This must be kept for the future traceability of the appliance.

OFFICINE VARISCO

SEND US A REQUEST, WE WILL REPLY AS SOON AS POSSIBLE!

FILL OUT THE FORM BELOW AND SEND YOUR INFORMATION REQUEST.
WE WILL REPLY THE FIRST POSSIBLE!